Show simple item record

dc.contributor.authorVakili, Samira
dc.contributor.authorLanting, Brent
dc.contributor.authorGetgood, Alan
dc.contributor.authorWilling, Ryan
dc.date.accessioned2024-04-24T22:43:24Z
dc.date.available2024-04-24T22:43:24Z
dc.date.copyright3/25/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_08_081005.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295753
dc.description.abstractA variety of total knee arthroplasty (TKA) designs offer increased congruency bearing options, primarily to compensate for a loss of posterior cruciate ligament (PCL) function. However, their efficacy in providing sufficient stability under different circumstances requires further investigation. The preclinical testing of prosthesis components on joint motion simulators is useful for quantifying how design changes affect joint stability. However, this type of testing may not be clinically relevant because surrounding ligaments are either ignored or greatly simplified. This study aimed to assess the kinematics and stability of TKA joints during various motions using condylar-stabilized (CS) bearings without a PCL versus cruciate-retaining (CR) bearings with an intact PCL. TKA prosthetic components were tested on a joint motion simulator while being stabilized with five different sets of specimen-specific virtual ligament envelopes. In comparison to CR knees, CS knees without a PCL exhibited a greater amount of posterior tibial displacement laxity, with a mean increase of 2.7±2.1 mm (p = 0.03). Additionally, significant differences were observed in the anterior–posterior kinematics of the knee joint during activities of daily living (ADL) between the two designs. These results were consistent with previous cadaveric investigations, which indicated that CS knees without a PCL are less resistant to posterior tibial displacement than CR knees with one. This study employing virtual ligaments confirms previous findings that the raised anterior lip of some CS bearings may not completely compensate for the absence of the PCL; however, as both studies used reduced joint contact forces, the contributions of this design feature may be attenuated.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleComparison of the Kinematics and Laxity of Total Knee Arthroplasty Bearing Designs Stabilized With Specimen-Specific Virtual Ligaments on a Joint Motion Simulator
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue8
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4064621
dc.journal.fristpage81005-1
dc.journal.lastpage81005-8
dc.page8
dc.treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record