Show simple item record

dc.contributor.authorZhou, Feng
dc.contributor.authorCheng, Quanyou
dc.contributor.authorZhao, Han
dc.contributor.authorZhang, Zongsheng
dc.contributor.authorWang, Hao
dc.date.accessioned2024-04-24T22:35:13Z
dc.date.available2024-04-24T22:35:13Z
dc.date.copyright2/2/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0195-0738
dc.identifier.otherjert_146_4_041702.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295491
dc.description.abstractIn response to the current problems such as electromagnetic coupling heating equipment relying on the limitations of electronic devices mostly and difficulty in achieving uniform heating of flowing material, this paper proposed a flowing heating system for pipelines of electromagnetic coupling of power frequency without the iron core. Using the heating system of 500 kW/10.5 kV, structural and electrical parameters were obtained from theoretical calculations, and a finite element simulation model was established. Aiming at the problems of voltage waveform distortion and low power factor, the factors affecting the heating system such as pipe wall thickness and coupling gap were analyzed, and the influence laws on the heating system were obtained. The structure of the conductive ring was proposed for system optimization. In the case of the no-iron heart, the heat efficiency can reach 89.01%, the power factor increased to 0.915, and the voltage distortion was also significantly reduced. Based on the finite element simulation results, the structure of the spoiler ball was proposed to address the problem of uneven heating, and the simulation showed that the spoiler balls can optimize the heating uniformity of the heating system. This system can realize the uniform heating of material without the cost of the iron core and has the characteristics of high voltage and high power, which can provide an effective way of thinking for the electric heating of hot water, steam, hot air, etc.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFlowing Heating System for Pipeline of Electromagnetic Coupling of Power Frequency Without the Iron Core and Its Structure Optimization
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue4
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4064525
dc.journal.fristpage41702-1
dc.journal.lastpage41702-12
dc.page12
dc.treeJournal of Energy Resources Technology:;2024:;volume( 146 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record