Show simple item record

dc.contributor.authorEmma Sarles, S.
dc.contributor.authorHensel, Edward C.
dc.contributor.authorTerry, Janessa
dc.contributor.authorNuss, Caleb
dc.contributor.authorRobinson, Risa J.
dc.date.accessioned2024-04-24T22:33:09Z
dc.date.available2024-04-24T22:33:09Z
dc.date.copyright2/9/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_04_045001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295431
dc.description.abstractCurrent in vitro emissions and exposure systems lack biomimicry, use unrealistic flow conditions, produce unrealistic dose, and provide inaccurate biomechanical cues to cell cultures, limiting ability to correlate in vitro outcomes with in vivo health effects. A biomimetic in vitro system capable of puffing aerosol and clean air inhalation may empower researchers to investigate complex questions related to lung injury and disease. A biomimetic aerosol exposure system (BAES), including an electronic cigarette adapter, oral cavity module (OCM), and bifurcated exposure chamber (BEC) was designed and manufactured. The fraction of aerosol deposited in transit to a filter pad or lost as volatiles was 0.116±0.021 in a traditional emissions setup versus 0.098 ± 0.015 with the adapter. The observed flowrate was within 5% of programed flowrate for puffing (25 mL/s), puff-associated respiration (450 mL/s), and tidal inhalation (350 mL/s). The maximum flowrate observed in the fabricated BAES was 450 mL/s, exceeding the lower target nominal wall shear stress of 0.025 Pa upstream of the bifurcation and fell below the target of 0.02 Pa downstream. This in vitro system addresses several gaps observed in commercially available systems and may be used to study many inhaled aerosols. The current work illustrates how in silico models may be used to correlate results of an in vitro study to in vivo conditions, rather than attempting to design an in vitro system that performs exactly as the human respiratory tract.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFlow Rate and Wall Shear Stress Characterization of a Biomimetic Aerosol Exposure System
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue4
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4064549
dc.journal.fristpage45001-1
dc.journal.lastpage45001-11
dc.page11
dc.treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record