Show simple item record

dc.contributor.authorStrick, Jacob A.
dc.contributor.authorFarris, Ryan J.
dc.contributor.authorSawicki, Jerzy T.
dc.date.accessioned2024-04-24T22:32:20Z
dc.date.available2024-04-24T22:32:20Z
dc.date.copyright1/29/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_04_044502.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295409
dc.description.abstractThis paper describes the development and evaluation of a novel, threshold-based gait event detection algorithm utilizing only one thigh inertial measurement unit (IMU) and unilateral, sagittal plane hip and knee joint angles. The algorithm was designed to detect heel strike (HS) and toe off (TO) gait events, with the eventual goal of detection in a real-time exoskeletal control system. The data used in the development and evaluation of the algorithm were obtained from two gait databases, each containing synchronized IMU and ground reaction force (GRF) data. All database subjects were healthy individuals walking in either a level-ground, urban environment or a treadmill lab environment. Inertial measurements used were three-dimensional thigh accelerations and three-dimensional thigh angular velocities. Parameters for the TO algorithm were identified on a per-subject basis. The GRF data were utilized to validate the algorithm's timing accuracy and quantify the fidelity of the algorithm, measured by the F1-Score. Across all participants, the algorithm reported a mean timing error of −41±20 ms with an F1-Score of 0.988 for HS. For TO, the algorithm reported a mean timing error of −1.4±21 ms with an F1-Score of 0.991. The results of this evaluation suggest that this algorithm is a promising solution to inertial based gait event detection; however, further refinement and real-time evaluation are required for use in exoskeletal control.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Novel Gait Event Detection Algorithm Using a Thigh-Worn Inertial Measurement Unit and Joint Angle Information
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue4
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4064435
dc.journal.fristpage44502-1
dc.journal.lastpage44502-7
dc.page7
dc.treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record