• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Applied Mechanics
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Applied Mechanics
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Investigating Viscoelastic Properties of Myofibrils Isolated From hiPSC-CMs Using Atomic Force Microscopy and Quasi-Linear Viscoelastic Model

    Thumbnail
    View/Open
    jam_91_1_011009.pdf (615.4Kb)
    Date
    2023
    Author
    Jannati, Shayan
    Maaref, Yasaman
    Tibbits, Glen F.
    Chiao, Mu
    Metadata
    Show full item record
    Abstract
    Knowing the mechanical properties of cardiac myofibrils isolated from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) can provide valuable insight into the structure and function of the heart muscle. Previous studies focused mostly on studying myofibrillar stiffness using simplified elastic models. In this study, the mechanical properties of myofibrils isolated from hiPSC-CMs were measured using atomic force microscopy (AFM). The quasi-linear viscoelastic (QLV) model was used to interpret the elastic and viscous properties of myofibrils. Since there have been no previous studies on the viscoelastic properties of myofibrils extracted from hiPSC-CMs, myofibrils extracted from porcine left-ventricular (LV) tissue were used to compare and verify experimental processes and QLV model parameters. The elastic modulus of myofibrils extracted from porcine LV tissue was determined to be 8.82 ± 6.09 kPa which is consistent with previous studies which reported that porcine LV tissue is less stiff on average than mouse and rat cardiac myofibrils. The elastic modulus of myofibrils extracted from hiPSC-CMs was found to be 9.78 ± 5.80 kPa, which is consistent with the range of 5–20 kPa reported for myofibrils extracted from the adult human heart. We found that myofibrils isolated from hiPSC-CMs relax slower than myofibrils extracted from porcine LV tissue, particularly in the first 0.25 s after the peak stress in the stress relaxation test. These findings provide important insights into the mechanical behavior of hiPSC-CMs and have implications for the development of treatments for heart diseases.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295339
    Collections
    • Journal of Applied Mechanics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV