Show simple item record

dc.contributor.authorCapobianchi, Massimo
dc.contributor.authorCangelosi, Richard
dc.date.accessioned2024-04-24T22:29:42Z
dc.date.available2024-04-24T22:29:42Z
dc.date.copyright3/20/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn2832-8450
dc.identifier.otherht_146_07_074501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295326
dc.description.abstractThis study details the derivation of a length correction term for computing the heat transfer performance of one-dimensional, straight, convecting-tip fins using the insulated-tip fin solution. Use of this corrected length in the insulated-tip fin solution produces the identical heat transfer rate and temperature profile as those computed using the more complex convecting-tip fin equations. The analysis derives the length correction equation from fundamental principles and produces a simple, closed-form expression valid for all fin cross-sectional shapes. Furthermore, the valid parameter range where this length correction is applicable, and outside of which no exact length correction is possible, is quantified.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExact Insulated-Tip Fin Length Correction for Tip Convection Compensation
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue7
dc.journal.titleASME Journal of Heat and Mass Transfer
dc.identifier.doi10.1115/1.4064827
dc.journal.fristpage74501-1
dc.journal.lastpage74501-6
dc.page6
dc.treeASME Journal of Heat and Mass Transfer:;2024:;volume( 146 ):;issue: 007
dc.contenttypeFulltext