Show simple item record

dc.contributor.authorRodriguez, Benjamin
dc.contributor.authorCampbell, Peter
dc.contributor.authorBorrello, Joseph
dc.contributor.authorOdland, Ian
dc.contributor.authorWilliams, Tyree
dc.contributor.authorHrabarchuk, Eugene I.
dc.contributor.authorYoung, Tirone
dc.contributor.authorSharma, Anirudh
dc.contributor.authorSchupper, Alexander J.
dc.contributor.authorRapoport, Benjamin
dc.contributor.authorIvkov, Robert
dc.contributor.authorHadjipanayis, Constantinos
dc.date.accessioned2024-04-24T22:24:30Z
dc.date.available2024-04-24T22:24:30Z
dc.date.copyright11/22/2023 12:00:00 AM
dc.date.issued2023
dc.identifier.issn0148-0731
dc.identifier.otherbio_146_01_011009.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295164
dc.description.abstractHigh-grade gliomas (HGG) are the most common primary brain malignancy and continue to be associated with a dismal prognosis (median survival rate of 15–18 months) with standard of care therapy. Magnetic hyperthermia therapy (MHT) is an emerging intervention that leverages the ferromagnetic properties of magnetic iron-oxide nanoparticles (MIONPs) to target cancer cells that are otherwise left behind after resection. We report a novel port device to facilitate localization, delivery, and temperature measurement of MIONPs within a target lesion for MHT therapy. We conducted an in-depth literature and intellectual property review to define specifications of the conceived port device. After setting the design parameters, a thorough collaboration with neurological surgeons guided the iterative modeling process. A prototype was developed using Fusion 360 (Autodesk, San Rafael, CA) and printed on a Form 3 printer (Formlabs, Medford, MA) in Durable resin. The prototype was then tested in a phantom skull printed on a Pro-Jet 660Pro 3D printer (3D Systems, Rock Hill, SC) and a brain model based on mechanical and electrochemical properties of native brain tissue. This phantom underwent MHT heating tests using an alternating magnetic field (AMF) sequence based on current MHT workflow. Successful localization, delivery, and temperature measurement were demonstrated. The purpose of this study was twofold: first, to create and validate the procedural framework for a novel device, providing the groundwork for an upcoming comprehensive animal trial and second, to elucidate a cooperative approach between engineers and clinicians that propels advancements in medical innovation.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Novel Port to Facilitate Magnetic Hyperthermia Therapy for Glioma
dc.typeJournal Paper
dc.journal.volume146
dc.journal.issue1
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4063556
dc.journal.fristpage11009-1
dc.journal.lastpage11009-8
dc.page8
dc.treeJournal of Biomechanical Engineering:;2023:;volume( 146 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record