Show simple item record

dc.contributor.authorCzakoj, Tomáš
dc.contributor.authorKošťál, Michal
dc.contributor.authorSchulc, Martin
dc.contributor.authorRypar, Vojtěch
dc.contributor.authorNovák, Evžen
dc.contributor.authorLosa, Evžen
dc.date.accessioned2023-11-29T19:35:10Z
dc.date.available2023-11-29T19:35:10Z
dc.date.copyright2/8/2023 12:00:00 AM
dc.date.issued2/8/2023 12:00:00 AM
dc.date.issued2023-02-08
dc.identifier.issn2332-8983
dc.identifier.otherners_009_03_032001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294876
dc.description.abstractCopper is an important material for the nuclear industry; therefore, the correct copper cross section are essential. This paper deals with benchmarking the fast neutron leakage spectrum from a copper block with an intense 252Cf source. The spectrum was measured by the proton recoil method using a stilbene scintillator and spectrometer with pulse shape discrimination. The room effect was subtracted experimentally by shielding cone and confirmed computationally. Simulations were performed using the MCNP6.2 Monte Carlo code. A detailed study on uncertainties has been made. Consequently, as the main source of uncertainties, the measurement apparatus was determined (namely, calibration and number of iterations—up to 15%). From the parameter uncertainty, the most important effects are connected with the mass of cube material—the thickness of the assembly (up to 2%). The effect of copper density uncertainty is low because density was determined experimentally with low uncertainty. The uncertainty related to parameter uncertainties in source structural components is negligible because even neglection of all components leads to a shift in leakage spectra below 7%. Several copper nuclear data libraries were tested as well, and it was found that the calculation with JEFF-3.3 gives the most discrepant results with a discrepancy of up to 60%. The closest results were obtained with ENDF/B-VIII.0 (below 5 MeV, discrepancy within 10%) and JENDL-4.0 (above 5 MeV, discrepancy within 15%). ENDF/B-VII.1 library is relatively close in the region above 5 MeV (discrepancy within 15%), below 5 MeV the agreement is worse (up to 40% discrepancy).
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleBenchmarking Fast Neutrons Leakage Spectrum From Copper Block With 252Cf Source in Center
dc.typeJournal Paper
dc.journal.volume9
dc.journal.issue3
dc.journal.titleJournal of Nuclear Engineering and Radiation Science
dc.identifier.doi10.1115/1.4056508
dc.journal.fristpage32001-1
dc.journal.lastpage32001-7
dc.page7
dc.treeJournal of Nuclear Engineering and Radiation Science:;2023:;volume( 009 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record