Show simple item record

dc.contributor.authorLindley, Ben
dc.contributor.authorÁlvarez Velarde, Francisco
dc.contributor.authorBaker, Una
dc.contributor.authorBodi, Janos
dc.contributor.authorCosgrove, Paul
dc.contributor.authorCharles, Alan
dc.contributor.authorFiorina, Carlo
dc.contributor.authorFridman, Emil
dc.contributor.authorKrepel, Jiri
dc.contributor.authorLavarenne, Jean
dc.contributor.authorMikityuk, Konstantin
dc.contributor.authorNikitin, Evgeny
dc.contributor.authorPonomarev, Alexander
dc.contributor.authorRadman, Stefan
dc.contributor.authorShwageraus, Eugene
dc.date.accessioned2023-11-29T19:34:27Z
dc.date.available2023-11-29T19:34:27Z
dc.date.copyright3/13/2023 12:00:00 AM
dc.date.issued3/13/2023 12:00:00 AM
dc.date.issued2023-03-13
dc.identifier.issn2332-8983
dc.identifier.otherners_009_03_031301.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294869
dc.description.abstractThe objective of this paper is to quantify the coupling effect on the power distribution of sodium-cooled fast reactors (SFRs), specifically the European SFR. Calculations are performed with several state-of-the-art reactor physics and Multiphysics codes (TRACE/PARCS, DYN3D, WIMS, COUNTHER, and GeN-Foam) to build confidence in the methodologies and validity of results. Standalone neutronic calculations were generally in excellent agreement with a reference Monte Carlo-calculated power distribution (from Serpent). Next, the impact of coolant density and fuel temperature Doppler feedback was calculated. Reactivity coefficients for perturbations in the inlet temperature, coolant heat up and core power was shown to be negative with values of around −0.5 pcm/°C, −0.3 pcm/°C, and −3.5 pcm/%, respectively. Fuel temperature and coolant density feedback was found to introduce a roughly −1%/+1% in/out power tilt across the core. Calculations were then extended to axial expansion for cases where fuel is linked and unlinked to the clad. Core calculations are in good agreement with each other. The impact of differential fuel expansion is found to be larger for fuel both linked and unlinked to the clad, with the in/out power tilt increasing to around −4%/+2%. Thus, while broadly confirming the known result that standalone physics calculations give good results, the expansion coupling effect is perhaps more than anticipated a priori. These results provide a useful benchmark for the further development of Multiphysics codes and methodologies in support of advanced reactor calculations.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleImpact of Thermal-Hydraulic Feedback and Differential Thermal Expansion on European Sodium-Cooled Fast Reactor Core Power Distribution
dc.typeJournal Paper
dc.journal.volume9
dc.journal.issue3
dc.journal.titleJournal of Nuclear Engineering and Radiation Science
dc.identifier.doi10.1115/1.4056930
dc.journal.fristpage31301-1
dc.journal.lastpage31301-13
dc.page13
dc.treeJournal of Nuclear Engineering and Radiation Science:;2023:;volume( 009 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record