• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Framework Development for Patient-Specific Compliant Aortic Dissection Phantom Model Fabrication: Magnetic Resonance Imaging Validation and Deep-Learning Segmentation

    Thumbnail
    View/Open
    bio_145_09_091010.pdf (3.097Mb)
    Date
    6/13/2023
    2023-06-13
    Author
    Aghilinejad, Arian
    Wei, Heng
    Bilgi, Coskun
    Paredes, Alberto
    DiBartolomeo, Alexander
    Magee, Gregory A.
    Pahlevan, Niema M.
    Metadata
    Show full item record
    Abstract
    Type B aortic dissection is a life-threatening medical emergency that can result in rupture of the aorta. Due to the complexity of patient-specific characteristics, only limited information on flow patterns in dissected aortas has been reported in the literature. Leveraging the medical imaging data for patient-specific in vitro modeling can complement the hemodynamic understanding of aortic dissections. We propose a new approach toward fully automated patient-specific type B aortic dissection model fabrication. Our framework uses a novel deep-learning-based segmentation for negative mold manufacturing. Deep-learning architectures were trained on a dataset of 15 unique computed tomography scans of dissection subjects and were blind-tested on 4 sets of scans, which were targeted for fabrication. Following segmentation, the three-dimensional models were created and printed using polyvinyl alcohol. These models were then coated with latex to create compliant patient-specific phantom models. The magnetic resonance imaging (MRI) structural images demonstrate the ability of the introduced manufacturing technique for creating intimal septum walls and tears based on patient-specific anatomy. The in vitro experiments show the fabricated phantoms generate physiologically-accurate pressure results. The deep-learning models also show high similarity metrics between manual segmentation and autosegmentation where Dice metric is as high as 0.86. The proposed deep-learning-based negative mold manufacturing method facilitates an inexpensive, reproducible, and physiologically-accurate patient-specific phantom model fabrication suitable for aortic dissection flow modeling.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294622
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV