    Design and Development of Patient-Specific Miniplate for the Treatment of Maxillofacial Fractures—A Finite Element Study

    Thumbnail
    View/Open
    jesmdt_006_03_030908.pdf (3.858Mb)
    Date
    6/7/2023 1
    2023-06-07
    Author
    Choudhury, Sandeep
    Banerjee, Anik
    Majumder, Santanu
    Chowdhury, Amit Roy
    Metadata
    Show full item record
    Abstract
    Fractures of the maxillofacial region are prevalent in both developed and developing nations. Maxillofacial fractures primarily occur as a result of incidents such as car crashes, physical assaults, and attacks. Although using miniplates to treat maxillofacial fractures is a widely accepted practice, the challenge lies in selecting the appropriate miniplate size that is tailored to the specific dimensions of the fracture in each patient. The study aims to evaluate and determine the most suitable design between a two-hole miniplate and a four-hole miniplate for securing a fractured mandible, with the ultimate goal of creating a customized solution for each patient. A mandible model is chosen with a diagonal length of 82 mm and created perpendicular fracture gaps measuring 1 mm to 3 mm on the left buccolingual section of the solid model. A two-hole and a four-hole miniplate are designed with different thicknesses (ranging from 1 mm to 2 mm) and gap distances (ranging from 6 mm to 12 mm). The miniplates were put together in a model of the mandible. To test their effectiveness, the combination of the mandible model and plates was subjected to various muscle forces, as well as the force of biting, using finite element analysis. At the mandible location, the four-hole miniplate implantation exhibits superior stabilization in comparison to the two-hole miniplate assembly. The miniplate's size and dimensions can be adjusted depending on the size of the fracture in the mandible, resulting in a patient-specific solution for the implantation of miniplate in the mandible.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294609
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV