Show simple item record

dc.contributor.authorBanerjee, Anik
dc.contributor.authorChoudhury, Sandeep
dc.contributor.authorRana, Masud
dc.contributor.authorChakraborty, Arindam
dc.contributor.authorGupta, Abhisek
dc.contributor.authorChowdhury, Amit Roy
dc.date.accessioned2023-11-29T19:08:26Z
dc.date.available2023-11-29T19:08:26Z
dc.date.copyright5/18/2023 12:00:00 AM
dc.date.issued5/18/2023 12:00:00 AM
dc.date.issued2023-05-18
dc.identifier.issn2572-7958
dc.identifier.otherjesmdt_006_03_030905.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294607
dc.description.abstractTemporomandibular joint replacement (TMJR) is a surgical procedure that relies heavily on the biomechanical properties of the implant-bone interface for success. In this study, we investigated the effects of three commonly used implant screw thread designs (buttress, square, and triangle) on the biomechanical performance of the mandibular bone-implant construct, with the aim of improving osseointegration. Using finite element analysis, we simulated the mechanical behavior of the prosthesis and mandible and examined the biomechanics of the temporomandibular joint. We considered five coefficients of friction ranging from 0.1 to 0.5 in our analyses. Our hypothesis was that changing the screw thread shape while keeping the pitch, height, and depth constant could enhance the biomechanical environment at the peri-implant bone. Our results indicate that the square thread design produced the highest stress concentration, while the triangle thread design exhibited the most favorable distribution of stress around the implant. Furthermore, increasing the coefficient of friction led to an increase in stress concentration in the implant and surrounding bone. Our findings offer valuable insights into the biomechanical performance of different screw thread designs in the mandibular bone-implant construct. They highlight the significance of considering screw thread shape and coefficient of friction in TMJR implant design. Future studies should incorporate the viscoelastic properties of bone to improve the accuracy of finite element analysis. This research contributes to the optimization of TMJR implants and ultimately enhances patient outcomes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleBiomechanical Analysis of Mandibular Bone-Implant Construct With Three Implant Screw Design: A Finite Element Study
dc.typeJournal Paper
dc.journal.volume6
dc.journal.issue3
dc.journal.titleJournal of Engineering and Science in Medical Diagnostics and Therapy
dc.identifier.doi10.1115/1.4062437
dc.journal.fristpage30905-1
dc.journal.lastpage30905-6
dc.page6
dc.treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2023:;volume( 006 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record