Show simple item record

dc.contributor.authorSun, Kai
dc.contributor.authorLiu, Xiangyun
dc.contributor.authorAo, Tingyu
dc.contributor.authorLiu, Liangde
dc.contributor.authorLiang, Zhu
dc.date.accessioned2023-11-29T19:03:24Z
dc.date.available2023-11-29T19:03:24Z
dc.date.copyright7/24/2023 12:00:00 AM
dc.date.issued7/24/2023 12:00:00 AM
dc.date.issued2023-07-24
dc.identifier.issn0195-0738
dc.identifier.otherjert_145_10_104501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294551
dc.description.abstractThis paper studies different experimental conditions for a 25t/h industrial boiler fueled with nature gas. In the meanwhile, numerical simulation is carried out using the commercial software of fluent. The different excess air coefficients of 1.05, 1.1, 1.15, 1.2, and 1.25 are studied. The different flue gas circulation rates of 5%, 10%, 15%, and 20% are studied compared with that rate of 0. The results show that the maximum temperature of the furnace and NOx emission concentration at the outlet increase first and then decrease with increasing excess air coefficient when flue gas circulation rate is 0, and the peak value of temperature and NOx emission concentration reaches 2071.93 K and 65.21 mg/m3 when excess air coefficient is 1.15, respectively. With increasing flue gas circulation rate, the average temperature of the furnace and the concentration of NOx at the outlet decreased, and the concentration of NOx decreased from 65.21 mg/m3 to 25 mg/m3. The higher the flue gas circulation, the smaller the high-temperature area of the furnace and the lower concentration of O2. However, excessively higher flue gas circulation rate and excess air coefficient can lead to incomplete combustion and lower coefficient. Hence, for optimizing the combustion conditions, the excess air coefficient and the flue gas circulation rate should be within an appropriate range.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperiment and Numerical Simulation Study of Low-Nitrogen Combustion Technology Inside Small Gas Boiler
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue10
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4062871
dc.journal.fristpage104501-1
dc.journal.lastpage104501-6
dc.page6
dc.treeJournal of Energy Resources Technology:;2023:;volume( 145 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record