Show simple item record

dc.contributor.authorMeadows, Kyle D.
dc.contributor.authorPeloquin, John M.
dc.contributor.authorMarkhali, Milad I.
dc.contributor.authorZgonis, Miltiadis H.
dc.contributor.authorSchaer, Thomas P.
dc.contributor.authorMauck, Robert L.
dc.contributor.authorElliott, Dawn M.
dc.date.accessioned2023-11-29T18:57:30Z
dc.date.available2023-11-29T18:57:30Z
dc.date.copyright5/31/2023 12:00:00 AM
dc.date.issued5/31/2023 12:00:00 AM
dc.date.issued2023-05-31
dc.identifier.issn0148-0731
dc.identifier.otherbio_145_08_081002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294489
dc.description.abstractThe meniscus serves important load-bearing functions and protects the underlying articular cartilage. Unfortunately, meniscus tears are common and impair the ability of the meniscus to distribute loads, increasing the risk of developing osteoarthritis. Therefore, surgical repair of the meniscus is a frequently performed procedure; however, repair does not always prevent osteoarthritis. This is hypothesized to be due to altered joint loading post-injury and repair, where the functional deficit of the meniscus prevents it from performing its role of distributing forces. The objective of this study was to quantify joint kinematics in an intact joint, after a meniscus root tear, and after suture repair in cadaveric porcine knees, a frequently used in vivo model. We utilized an magnetic resonance images-compatible loading device and novel use of a T1 vibe sequence to measure meniscus and femur displacements under physiological axial loads. We found that anterior root tear led to large meniscus displacements under physiological axial loading and that suture anchor repair reduced these displacements but did not fully restore intact joint kinematics. After tear and repair, the anterior region of the meniscus moved posteriorly and medially as it was forced out of the joint space under loading, while the posterior region had small displacements as the posterior attachment acted as a hinge about which the meniscus pivoted in the axial plane. Methods from this study can be applied to assess altered joint kinematics following human knee injuries and evaluate repair strategies aimed to restore joint kinematics.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAcute Repair of Meniscus Root Tear Partially Restores Joint Displacements as Measured With Magnetic Resonance Images and Loading in a Cadaveric Porcine Knee
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue8
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4062524
dc.journal.fristpage81002-1
dc.journal.lastpage81002-9
dc.page9
dc.treeJournal of Biomechanical Engineering:;2023:;volume( 145 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record