Show simple item record

dc.contributor.authorD'Andrea, Luca
dc.contributor.authorCardamone, Maddalena
dc.contributor.authorBogoni, Francesca
dc.contributor.authorForzinetti, Elisa
dc.contributor.authorEnei, Viviana
dc.contributor.authorValle, Francesco
dc.contributor.authorGiordano, Giovanni
dc.contributor.authorGastaldi, Dario
dc.contributor.authorVena, Pasquale
dc.date.accessioned2023-11-29T18:38:59Z
dc.date.available2023-11-29T18:38:59Z
dc.date.copyright1/11/2023 12:00:00 AM
dc.date.issued1/11/2023 12:00:00 AM
dc.date.issued2023-01-11
dc.identifier.issn0148-0731
dc.identifier.otherbio_145_03_031009.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294289
dc.description.abstractIn this work, we present a new experimental setup for the assessment of the anisotropic properties of Bovine Pericardium (BP) membranes. The chemically fixed BP samples have been subjected to a bulge test with in situ confocal laser scanning at increasing applied pressure. The high resolution topography provided by the confocal laser scanning has allowed to obtain a quantitative measure of the bulge displacement; after polynomial fitting, principal curvatures have been obtained and a degree of anisotropy (DA) has been defined as the normalized difference between the maximum and minimum principal curvatures. The experiments performed on the BP membranes have allowed us to obtain pressure-displacement data which clearly exhibit distinct principal curvatures indicating an anisotropic response. A comparison with curvatures data obtained on isotropic Nitrile Buthadiene Rubber (NBR) samples has confirmed the effectiveness of the experimental setup for this specific purpose. Numerical simulations of the bulge tests have been performed with the purpose of identifying a range of constitutive parameters which well describes the obtained range of DA on the BP membranes. The DA values have been partially validated with biaxial tests available in literature and with suitably performed uni-axial tensile tests.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnisotropic Mechanical Response of Bovine Pericardium Membrane Through Bulge Test and In-Situ Confocal-Laser Scanning
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue3
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4056398
dc.journal.fristpage31009-1
dc.journal.lastpage31009-8
dc.page8
dc.treeJournal of Biomechanical Engineering:;2023:;volume( 145 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record