• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effects of Infilled Walls with and without Openings on Progressive Collapse Resistance of Steel Frames under Corner Column Loss Condition

    Thumbnail
    View/Open
    JSENDH.STENG-12268.pdf (2.046Mb)
    Date
    5/23/2023
    2023-05-23
    Author
    Kai Qian
    Xi Lan
    Xiao-Fang Deng
    Zhi Li
    Metadata
    Show full item record
    Abstract
    Steel frames may have an inherent ability to resist progressive collapse through alternative load-resisting mechanisms, including Vierendeel, flexural, catenary, and membrane actions. Among the columns at different positions, corner column failure caused by accidental loading is more dangerous due to the relatively few alternative load-resisting mechanisms. To evaluate the effects of infilled walls with or without openings on the progressive collapse resistance of steel frames, four two-span 2-story steel frames were tested in this study. According to the test results, the solid infilled frames achieved peak loads that were over 300% greater than those of the bare frame. Relative to the bare frame, the infilled frames with solid bricks and perforated bricks increased the deflection capacities by 15% and 29%, respectively. This result was attributed to the development of effective compressive struts in the infilled walls to partially transfer the vertical loads. Thus, premature joint failure was avoided. Moreover, the failure modes of the infilled walls changed when different types of brick were adopted. The infilled walls with solid bricks showed extensive shear sliding cracks; the infilled walls with perforated bricks were relatively intact, but the compressive corners were crushed. The partially infilled frame with a 40% opening ratio still increased the load-resisting capacity of the steel frame by 90%. In addition, the efficiencies of the compressive strut models of the infilled walls under corner column loss conditions were evaluated. Based on the calculations, the width of the equivalent compressive strut provided by current US standards is recommended.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294153
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV