    Numerical Study on Coal–Sludge Cocombustion Characteristics and NOx Emission Behaviors in a 330-MW Wall-Fired Boiler

    Thumbnail
    View/Open
    JLEED9.EYENG-4856.pdf (4.149Mb)
    Date
    6/21/2023
    2023-06-21
    Author
    Qiang Lyu
    Chang’an Wang
    Pengbo Zhao
    Lei Zhou
    Yujie Hou
    Meijing Chen
    Yongbo Du
    Defu Che
    Metadata
    Show full item record
    Abstract
    Cofiring sludge with coal based on existing power plants is a promising method to realize harmless recycling treatment for sludge disposal. However, the influences of sludge addition on NOx emission are still controversial. Moreover, the optimal operating strategies for the cocombustion boiler need further investigations. In this study, the influences of sludge blending ratio, moisture content, sludge inlet position, and air-staging parameter on the combustion characteristics and NOx emission behaviors in a 330-MW boiler were analyzed numerically. The results show that with the increase of sludge blending ratio, the flue gas temperature in the primary zone decreases. The overall burnout ratio declines with the addition of sludge due to the higher ash and moisture contents. Although the sludge contains more N than coal, the NOx emissions in the cofiring case are lower than those in the coal-fired case due to the lower temperature and stronger reducing atmosphere in the primary zone. Reducing the moisture in the sludge is beneficial to the combustion within the furnace. Nevertheless, because of the higher temperature and lower CO concentration within the furnace, the NOx concentration at the furnace outlet increases. For wall-fired boilers, feeding the sludge from the lower burners should be avoided considering the potential surge in NOx emission. When the excess air ratio in the primary zone increases from 0.74 to 0.96, the NOx concentration at the furnace outlet rises by 58%. Hence, although relatively lower excess air ratio in the primary zone could bring adverse impacts on the burnout behaviors, air-staging combustion is still necessary when cofiring sludge in the coal-fired boiler.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4293709
    Collections
    • Journal of Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV