dc.description.abstractFeed water pretreatment commonly is required for low-pressure membrane technologies employed in drinking water treatment applications to reduce membrane fouling and create stable operating conditions. Comparatively few studies have investigated coagulation–flocculation–dissolved air flotation (CF-DAF) pretreatment for drinking water applications, and none have compared CF-DAF, coagulation–flocculation–sedimentation (CF-S), and in-line coagulation (CF-IN) pretreatments using the same water. This study compared these three pretreatments for the filtration of a high dissolved organic carbon (DOC), high hydrophobic (HPO) surface water using a hydrophilic polyvinylidene fluoride (h-PVDF) ultrafiltration (UF) fiber. Multiday filtration tests were carried out using an automated bench-scale testing system operated in an outside-in configuration. CF-S and CF-DAF were found to be equally effective at mitigating membrane fouling, although CF-DAF pretreated water had a lower residual DOC and the greatest removal of UV254 absorbent organics. Compared with CF-DAF and CF-S, CF-IN pretreatment resulted in higher levels of total and irreversible fouling regardless of the applied coagulant dose. For all the pretreatments studied, irreversible membrane fouling was found to be strongly dependent on both the hydrophobicity of the feed water [in terms of specific UV absorbance (SUVA)] and the concentration of the 5–10-kDa DOC fraction, suggesting that the HPO humic organics were the principal foulant for this membrane–water combination. CF-IN pretreatment performance also was strongly impacted by the feed water zeta potential, suggesting that the characteristics of the formed flocculant particles are critical to the fouling behavior of the hybrid CF-IN-UF system.
dc.publisherAmerican Society of Civil Engineers
dc.titleComparing Sedimentation, Flotation, and In-Line Pretreatment for Low-Pressure Membrane Fouling Reduction
dc.typeJournal Article
dc.journal.volume149
dc.journal.issue4
dc.journal.titleJournal of Environmental Engineering
dc.identifier.doi10.1061/JOEEDU.EEENG-7070
dc.journal.fristpage04023002-1
dc.journal.lastpage04023002-17
dc.page17
dc.treeJournal of Environmental Engineering:;2023:;Volume ( 149 ):;issue: 004