• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Hydrologic Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Hydrologic Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Hydrologic Performance of Permeable Pavers and a Dome Concrete Forming System: A Comparative Study

    Thumbnail
    View/Open
    JHYEFF.HEENG-5804.pdf (6.304Mb)
    Date
    2023/03/01
    Author
    Tamer Almaaitah
    Mikhail Moshe
    Alexus Maglalang
    Darko Joksimovic
    James Li
    Metadata
    Show full item record
    Abstract
    The hydrologic performance of permeable interlocking concrete pavers (PICP) and a dome concrete forming system (DCFS) was quantified and evaluated at a retrofitted residential laneway in Toronto, Ontario. The quantification and evaluation were performed by comparing their monitored performance over 14 months with an adjacent concrete pavement. Their monitored performance was then used to assess their ability to mimic predevelopment hydrologic behavior, estimated through modeling. The PICP and DCFS achieved (1) an average runoff volume reduction of 33% and 85%; (2) an average runoff coefficient of 0.48 and 0.12; and (3) an average peak flow reduction of 43% and 89%, respectively. The outflow duration from the DCFS was extended 4.1 times greater than the inflow duration, indicating its potential to attenuate flashy events. The peak flows produced by the DCFS were delayed by nearly 2.5 h from those occurring on the PICP. Correlation analyses indicated a more significant influence of rainfall depth and intensity on the performance of PICP than that of the DCFS. Compared with predevelopment levels, PICP did not match runoff volumes for smaller events (<10  mm) but produced less runoff for larger events (>30  mm). However, the PICP did not match predevelopment peak flows in 100% of occurrences. The DCFS reduced runoff volumes and peak flows to magnitudes lower than all predevelopment levels. Surface infiltration testing and subsurface hydraulic conductivity estimations indicated that infiltration capability in both systems could be reduced over time. The study demonstrated that the DCFS might need to be prioritized over permeable pavements, especially when installed over low-permeability soils.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292796
    Collections
    • Journal of Hydrologic Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV