• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Energy Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Energy Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comprehensive Day-Ahead Marketing Model Considering N-1 Security and Renewables

    Thumbnail
    View/Open
    (ASCE)EY.1943-7897.0000866.pdf (2.655Mb)
    Date
    2023/02/01
    Author
    Karina Tyroller
    Tankut Yalcinoz
    Krzysztof Rudion
    Metadata
    Show full item record
    Abstract
    Integrating renewable energies into the electricity grid is a challenge that requires an in-depth investigation. This paper presents a model of the day-ahead electricity market, including wind and photovoltaic (PV) generators, and contingency analysis. The comprehensive day-ahead marketing model is designed as a modular structure so that the individual modules can be easily modified in the future. First, the day-ahead electricity marketing of an electricity grid with and without renewable energies is studied. A market model solves the problem of unit commitment and economic dispatch. A grid model was used to calculate the power flow of the branches and the grid losses. Congestions in the branches were handled by redispatching. For this purpose, the generators were redispatched using mixed-integer linear programming and the power transfer distribution factor. A contingency analysis, investigating the outage of one branch, was applied by using the line outage distribution factor. The redispatch process was operated with these calculated increased power flows, which need to be handled by the grid to achieve N-1 security. The simulations were carried out using 30-bus 118-bus systems. Historic wind speed and solar radiation data of Germany were used as input data for renewable energy production. The load data of the 118-bus system were generated based on a standard load profile from Germany. The results show that both systems were able to meet the demand without violation of the grid capacity during normal conditions, with and without renewable energies. However, when applying the contingency analysis, an outrageous amount of load curtailment is needed.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292723
    Collections
    • Journal of Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV