Show simple item record

dc.contributor.authorTiwari, Gopal Nath
dc.contributor.authorSingh, Rohit Kumar
dc.contributor.authorSinha, Akhoury Sudhir Kumar
dc.contributor.authorSingh, Amit Kumar
dc.date.accessioned2023-08-16T18:51:30Z
dc.date.available2023-08-16T18:51:30Z
dc.date.copyright4/5/2023 12:00:00 AM
dc.date.issued2023
dc.identifier.issn0199-6231
dc.identifier.othersol_145_6_061003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292602
dc.description.abstractThe opaque photovoltaic thermal (PVT) produces both thermal and electrical energy. In order to increase thermal energy, we have considered flexible (Al-based) photovoltaic (PV) module for the present study. Further, we have considered thermo-electric cooler (TEC) integrated with flexible PV module to enhance electrical power. As a result, an overall power can be increased in flexible PVT-TEC collector. A concept of series and parallel combination of flexible PVT-TEC collectors is proposed to optimize series (n) and parallel (m) combinations for a given number of N (=n × m) collectors for maximum overall exergy depending on thermal and electrical energies which have not been considered yet so far. Further, a new expression has also been developed for the heat removal factor and instantaneous thermal efficiency of the nth flexible PVT-TEC collector to investigate its effect on the nth flexible PVT-TEC collector performance. Numerical computations have been carried out for a given coldest climatic condition of Srinagar, India, and design parameters of Al-based PVT-TEC collectors using matlab R2021b. Based on numerical computations, the following conclusions have been drawn: (i) For case (a) (all flexible PVT-TEC collectors are connected in parallel), the daily overall exergy is 2.7 kW, which is 21.3% more than case (d). (All flexible PVT-TEC collectors are connected in series.) (ii) There is a drop of 20% in the mass flowrate factor due to the correction factor.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleStudy of Performance of the Flexible (Al-Based) N-PVT-TEC Collectors in Different Configurations
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue6
dc.journal.titleJournal of Solar Energy Engineering
dc.identifier.doi10.1115/1.4062171
dc.journal.fristpage61003-1
dc.journal.lastpage61003-11
dc.page11
dc.treeJournal of Solar Energy Engineering:;2023:;volume( 145 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record