Show simple item record

dc.contributor.authorLadak, Aman
dc.contributor.authorHajjar, Roger J.
dc.contributor.authorMurali, Srinivas
dc.contributor.authorMichalek, Jeremy J.
dc.contributor.authorRiviere, Cameron N.
dc.date.accessioned2023-08-16T18:45:00Z
dc.date.available2023-08-16T18:45:00Z
dc.date.copyright4/17/2023 12:00:00 AM
dc.date.issued2023
dc.identifier.issn1932-6181
dc.identifier.othermed_017_02_021006.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292431
dc.description.abstractHeartPrinter is a novel under-constrained 3-cable parallel wire robot designed for minimally invasive epicardial interventions. The robot adheres to the beating heart using vacuum suction at its anchor points, with a central injector head that operates within the triangular workspace formed by the anchors, and is actuated by cables for multipoint direct gene therapy injections. Minimizing cable tensions can reduce forces on the heart at the anchor points while supporting rapid delivery of accurate injections and minimizing procedure time, risk of damage to the robot, and strain to the heart. However, cable tensions must be sufficient to hold the injector head's position as the heart moves and to prevent excessive cable slack. We pose a linear optimization problem to minimize the sum of cable tension magnitudes for HeartPrinter while ensuring the injector head is held in static equilibrium and the tensions are constrained within a feasible range. We use Karush-Kuhn-Tucker optimality conditions to derive conditional algebraic expressions for optimal cable tensions as a function of injector head position and workspace geometry, and we identify regions of injector head positions where particular combinations of cable tensions are optimally at minimum allowable tensions. The approach can rapidly solve for the minimum set of cable tensions for any robot workspace geometry and injector head position and determine whether an injection site is attainable.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleCable Tension Optimization for an Epicardial Parallel Wire Robot
dc.typeJournal Paper
dc.journal.volume17
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4056866
dc.journal.fristpage21006-1
dc.journal.lastpage21006-11
dc.page11
dc.treeJournal of Medical Devices:;2023:;volume( 017 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record