Show simple item record

dc.contributor.authorYue, Wanli
dc.contributor.authorCui, Haipo
dc.contributor.authorSong, Chengli
dc.contributor.authorTu, Liangyong
dc.contributor.authorLang, Jingcheng
dc.contributor.authorYan, Wenhui
dc.contributor.authorLu, Yingxi
dc.date.accessioned2023-08-16T18:44:26Z
dc.date.available2023-08-16T18:44:26Z
dc.date.copyright11/8/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn1932-6181
dc.identifier.othermed_017_01_011002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292415
dc.description.abstractColorectal cancer is a common malignant tumor in the gastrointestinal tract. Resection of the cancerous site and anastomosis of the residual intestine is the preferred radical treatment for colorectal cancer. In particular, radio frequency energy anastomosis of the residual intestine is being increasingly used in clinical practice. To improve the quality of anastomosis, reduce the thermal damage of tissue near the anastomosis area, and avoid foreign body residue in this area, we propose a self-cooling eversion-type radio frequency-energy intestinal anastomosis electrode, which is analyzed through simulations and evaluated experimentally for welding intestinal tissue. For radio frequency energy power of 160 W, anastomosis time of 13.2 s, and pressure of 154 kPa, the disconnected intestinal tissues can be anastomosed using the proposed electrode. The average burst pressure of the anastomotic orifice is 43.86 mmHg. During welding, the temperature of the normal saline at the outlet is 6.8 °C higher than that at the inlet, indicating that the use of circulating normal saline as the conductive and cooling medium can dissipate part of the heat generated by welding and reduce heat accumulation, thereby reducing thermal damage of biological tissue near the welding area. Overall, the proposed electrode may contribute to the recovery of postoperative intestinal function by enabling a novel strategy for clinical intestinal anastomosis induced by radio frequency energy.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDesign and Evaluation of Self-Cooling Electrodes for Radiofrequency Intestinal Anastomosis
dc.typeJournal Paper
dc.journal.volume17
dc.journal.issue1
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4056008
dc.journal.fristpage11002-1
dc.journal.lastpage11002-7
dc.page7
dc.treeJournal of Medical Devices:;2022:;volume( 017 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record