Show simple item record

dc.contributor.authorYeni, Yener N.
dc.contributor.authorOravec, Daniel
dc.contributor.authorDrost, Joshua
dc.contributor.authorZauel, Roger
dc.contributor.authorFlynn, Michael J.
dc.date.accessioned2023-08-16T18:39:18Z
dc.date.available2023-08-16T18:39:18Z
dc.date.copyright12/5/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_145_04_041009.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292278
dc.description.abstractVertebral fractures are the most common osteoporotic fractures, but their prediction using standard bone mineral density (BMD) measurements from dual energy X-ray absorptiometry (DXA) is limited in accuracy. Stiffness, displacement, and strain distribution properties derived from digital tomosynthesis-based digital volume correlation (DTS-DVC) have been suggested as clinically measurable metrics of vertebral bone quality. However, the extent to which these properties correlate to vertebral strength is unknown. To establish this relationship, two independent experiments, one examining isolated T11 and the other examining L3 vertebrae within the L2–L4 segments from cadaveric donors were utilized. Following DXA and DTS imaging, the specimens were uniaxially compressed to fracture. BMD, bone mineral content (BMC), and bone area were recorded for the anteroposterior and lateromedial views from DXA, stiffness, endplate to endplate displacement and distribution statistics of intravertebral strains were calculated from DTS-DVC and vertebral strength was measured from mechanical tests. Regression models were used to examine the relationships of strength with the other variables. Correlations of BMD with vertebral strength varied between experimental groups (R2adj = 0.19–0.78). DTS-DVC derived properties contributed to vertebral strength independently from BMD measures (increasing R2adj to 0.64–0.95). DTS-DVC derived stiffness was the best single predictor (R2adj = 0.66, p < 0.0001) and added the most to BMD in models of vertebral strength for pooled T11 and L3 specimens (R2adj = 0.95, p < 0.0001). These findings provide biomechanical relevance to DTS-DVC calculated properties of vertebral bone and encourage further efforts in the development of the DTS-DVC approach as a clinical tool.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleStiffness and Strain Properties Derived From Digital Tomosynthesis-Based Digital Volume Correlation Predict Vertebral Strength Independently From Bone Mineral Density
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue4
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4056196
dc.journal.fristpage41009-1
dc.journal.lastpage41009-8
dc.page8
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 145 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record