Show simple item record

dc.contributor.authorNascimento, Diego Henrique Antunes
dc.contributor.authorMagalhães, Fabrício Anicio
dc.contributor.authorSabino, George Schayer
dc.contributor.authorResende, Renan Alves
dc.contributor.authorDuarte, Maria Lúcia Machado
dc.contributor.authorVimieiro, Claysson Bruno Santos
dc.date.accessioned2023-08-16T18:38:00Z
dc.date.available2023-08-16T18:38:00Z
dc.date.copyright12/5/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_145_04_041006.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292244
dc.description.abstractSensorized insoles (SIs) have been used as a wearable instrument to study human gait and have the potential to identify and predict pathologies and injuries. However, most of these sensorized insoles are only statically calibrated, relying on a scale and known weights to establish a relationship between electrical signals and the load applied on laboratory benches while ignoring the dynamic interaction between person and instrument. This study proposes and verifies a calibration method complementary to static calibration to compensate for different dynamic interactions between the insole and the individual during gait. In order to perform this comparison, a laboratory test was proposed with 32 volunteers (18 men and 14 women). Each volunteer walked on a double-belt instrumented treadmill (Bertec at 1000 Hz, Bertec Corp, Columbus, OH) while wearing an experimental resistive sensorized insole (SI). The SI data were compared with the instrumented treadmill and adjusted using an optimization algorithm to create a dynamic coefficient to complement and optimize the results. This study also verifies the impact of the method considering three different types of gait: pronated, neutral, and supinated. After using this technique and considering static calibration, the Pearson correlation coefficient between the SI and the instrumented treadmill improved by 12%.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleNew Optimized Dynamic Calibration Proposition for Discretized Sensorized Insoles With Resistive Force Sensor: A Descriptive and Comparative Study
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue4
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4056061
dc.journal.fristpage41006-1
dc.journal.lastpage41006-7
dc.page7
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 145 ):;issue: 004
dc.contenttypeFulltext