Show simple item record

dc.contributor.authorProst, Victor
dc.contributor.authorJohnson, W. Brett
dc.contributor.authorKent, Jenny A.
dc.contributor.authorMajor, Matthew J.
dc.contributor.authorWinter, Amos G., V
dc.date.accessioned2023-08-16T18:36:39Z
dc.date.available2023-08-16T18:36:39Z
dc.date.copyright12/5/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_145_04_041002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292211
dc.description.abstractAdvances in understanding the effects the mechanical characteristics of prosthetic feet on user biomechanics have enabled passive prostheses to improve the walking pattern of people with lower limb amputation. However, there is no consensus on the design methodology and criteria required to maximize specific user outcomes and fully restore their mobility. The Lower Leg Trajectory Error (LLTE) framework is a novel design methodology based on the replication of lower leg dynamics. The LLTE value evaluates how closely a prosthetic foot replicates a target walking pattern. Designing a prosthesis that minimizes the LLTE value, optimizes its mechanical function to enable users to best replicate the target lower leg trajectory. Here, we conducted a systematic sensitivity investigation of LLTE-optimized prostheses. Five people with unilateral transtibial amputation walked overground at self-selected speeds using five prototype energy storage and return feet with varying LLTE values. The prototypes' LLTE values were varied by changing the stiffness of the participant's LLTE-optimized design by 60%, 80%, 120%, and 167%. Users most closely replicated the target able-bodied walking pattern with the LLTE-optimized stiffness, experimentally demonstrating that the predicted optimum was a true optimum. Additionally, the predicted LLTE values were correlated to the user's ability to replicate the target walking pattern, user preferences, and clinical outcomes including roll-over geometries, trunk sway, prosthetic energy return, and peak push-off power. This study further validates the use of the LLTE framework as a predictive and quantitative tool for designing and evaluating prosthetic feet.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleSystematic Assessment of Prosthesis Stiffness on User Biomechanics Using the Lower Leg Trajectory Error Framework and Its Implication for the Design and Evaluation of Ankle-Foot Prostheses
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue4
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4056137
dc.journal.fristpage41002-1
dc.journal.lastpage41002-16
dc.page16
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 145 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record