Show simple item record

dc.contributor.authorSeifert, Jack
dc.contributor.authorKoser, Jared
dc.contributor.authorShah, Alok S.
dc.contributor.authorFrazer, Lance L.
dc.contributor.authorYoganandan, Narayan
dc.contributor.authorShender, Barry S.
dc.contributor.authorSheehy, James B.
dc.contributor.authorPaskoff, Glenn
dc.contributor.authorBentley, Timothy
dc.contributor.authorNicolella, Daniel P.
dc.contributor.authorStemper, Brian D.
dc.date.accessioned2023-08-16T18:35:32Z
dc.date.available2023-08-16T18:35:32Z
dc.date.copyright12/5/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_145_03_031004.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292178
dc.description.abstractBody armor is used to protect the human from penetrating injuries, however, in the process of defeating a projectile, the back face of the armor can deform into the wearer at extremely high rates. This deformation can cause a variety of soft and hard tissue injuries. Finite element modeling (FEM) represents one of the best tools to predict injuries from this high-rate compression mechanism. However, the validity of a model is reliant on accurate material properties for biological tissues. In this study, we measured the stress–strain response of thoraco-abdominal tissue during high-rate compression (1000 and 1900 s−1) using a split Hopkinson pressure bar (SHPB). High-rate material properties of porcine adipose, heart, spleen, and stomach tissue were characterized. At a strain rate of 1000 s−1, adipose (E = 4.7 MPa) had the most compliant stress–strain response, followed by spleen (E = 9.6 MPa), and then heart tissue (E = 13.6 MPa). At a strain rate of 1900 s−1, adipose (E = 7.3 MPa) had the most compliant stress–strain response, followed by spleen (E = 10.7 MPa), heart (E = 14.1 MPa), and stomach (E = 32.6 MPa) tissue. Only adipose tissue demonstrated a consistent rate dependence for these high strain rates, with a stiffer response at 1900 s−1 compared to 1000 s−1. However, comparison of all these tissues to previously published quasi-static and intermediate dynamic experiments revealed a strong rate dependence with increasing stress response from quasi-static to dynamic to high strain rates. Together, these findings can be used to develop a more accurate finite element model of high-rate compression injuries.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleResponse of Thoraco-Abdominal Tissue in High-Rate Compression
dc.typeJournal Paper
dc.journal.volume145
dc.journal.issue3
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4056062
dc.journal.fristpage31004-1
dc.journal.lastpage31004-7
dc.page7
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 145 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record