• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Fluids Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Fluids Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Thermodynamic Suppression Effect of Cavitation Arising in a Hydrofoil in 140 °C Hot Water

    Thumbnail
    View/Open
    fe_145_01_011207.pdf (2.356Mb)
    Date
    2022
    Author
    Iga, Yuka
    Okajima, Junnosuke
    Yamagichi, Yuki
    Sasaki, Hirotoshi
    Ito, Yu
    Metadata
    Show full item record
    Abstract
    The thermodynamic suppression effect of cavitation arising in a NACA0015 single hydrofoil is experimentally investigated in water at mainstream temperatures of T∞ = 20 °C to 140 °C in the present study. The cavity length at T∞ = 140 °C is shorter than that at T∞ = 20 °C at a constant cavitation number for all cavity patterns from inception to supercavitation. On the other hand, the cavity length at T∞ = 80 °C is slightly shorter than that at 20 °C in a certain region in which unsteady sheet-cloud cavitation occurs. This indicates that the thermodynamic suppression effect appears easily in unsteady cavitation. In addition, the temperature reduction inside cavities in water is accurately measured using thermistors, which are inserted from the sidewall directly into the cavity. The temperature measurement is performed at a mainstream temperature of less than 80 °C due to limitation of calibration for the sensor. The temperature reduction at 140 °C is then predicted from the measured cavity length. It is shown that the temperature reduction inside the cavity is approximately ΔT = 0.3 °C at T∞ = 80 °C and ΔT = 0.05 °C at T∞ = 20 °C under supercavitation conditions. The predicted temperature reduction inside the cavity is ΔT = 1.1 K at T∞ = 140 °C under supercavitation conditions. Finally, Fruman's prediction equation for ΔT is examined by fitting to the measured and predicted ΔT values with assuming a volume coefficient of evaporation CQ as a fitting parameter.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4291721
    Collections
    • Journal of Fluids Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV