Show simple item record

dc.contributor.authorAmanpreet Singh
dc.contributor.authorXiang Wang
dc.contributor.authorZhidong Zhang
dc.contributor.authorFani Derveni
dc.contributor.authorHernan Castaneda
dc.contributor.authorKara D. Peterman
dc.contributor.authorBenjamin W. Schafer
dc.contributor.authorTara C. Hutchinson
dc.date.accessioned2023-04-07T00:36:25Z
dc.date.available2023-04-07T00:36:25Z
dc.date.issued2022/12/01
dc.identifier.other%28ASCE%29ST.1943-541X.0003433.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4289377
dc.description.abstractThe North American construction industry has seen substantial growth in the use of cold-formed steel (CFS) framing for midrise buildings in recent years. In seismic zones, CFS-framed buildings utilize shear walls to provide the primary lateral resistance to earthquake induced loads. Although oriented strand board (OSB) and plywood panels have been traditionally used as the sheathing material for these essential components, more recently, steel sheet sheathing has emerged as a novel strategy due to its strength, ductility, ease of installation, and use of noncombustible material, among other benefits. To address the paucity of data regarding CFS-framed shear wall response within actual wall lines of buildings, a two-phased experimental effort was conducted. Wall-line assemblies were fabricated and tested with shear walls placed in-line with gravity walls. The shear walls chord stud packs include tie-rod assemblies consistent with multi-story detailing. Specimens were either unfinished or finished, and the shear walls were laid out in a symmetrical or unsymmetrical fashion within in the wall line. In addition, both Type I and Type II shear wall and anchorage detailing were investigated. In this paper, the impact of test variables governing the structural detailing of CFS-framed walls are quantified through dynamic and quasi-static tests, and a companion paper presents findings regarding the impact of architectural variations on seismic performance.
dc.publisherASCE
dc.titleSteel Sheet Sheathed Cold-Formed Steel Framed In-line Wall Systems. I: Impact of Structural Detailing
dc.typeJournal Article
dc.journal.volume148
dc.journal.issue12
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0003433
dc.journal.fristpage04022193
dc.journal.lastpage04022193_18
dc.page18
dc.treeJournal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 012
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record