• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Void Fraction Measurement and Prediction of Two-Phase Boiling Flows in a Tubular Test Section

    Thumbnail
    View/Open
    ners_009_02_021403.pdf (3.591Mb)
    Date
    2022
    Author
    Liu, Qingqing;Diaz, Julio;Petrov, Victor;Burak, Adam;Manera, Annalisa;Kelly, Joseph;Sun, Xiaodong
    Metadata
    Show full item record
    Abstract
    Void fraction is one of the most important parameters that affect two-phase flow heat transfer and pressure drop. In this paper, a commercial gamma densitometer and a high-speed X-ray radiography system developed at the University of Michigan (UM) are used to measure the void fraction in two-phase boiling flows, with water as the working fluid, in a tubular test section. The test section is made of Incoloy 800H/HT with a total length of 1.589 m, an inner diameter of 12.95 mm, and a wall thickness of 3.05 mm. These two instrumentation systems are installed on a traversing platform that travels along the vertical test section to perform measurements at multiple elevations. Subcooled flow boiling and natural convection boiling experiments are performed to measure the void fraction in the test section. Flow visualization images are obtained for bubbly and slug flows from the X-ray radiography system. The wall temperature of the test section is measured at 17 elevations by thermocouples. In addition to the experiments, a multiphase computational fluid dynamics (MCFD) model is developed using ansysfluent to simulate the subcooled flow boiling. The measured wall temperature and void fraction from the experiments are compared with the MCFD simulation results. The root-mean-square (RMS) relative deviations are 3.6% and 16.1% for the wall temperature and void fraction, respectively, between the experimental data and MCFD simulations.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4288381
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV