• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Applicability of the Dose Spiking Electron Paramagnetic Resonance Method for the Quantitative Measurements of Low Doses in Alanine Dosimetry

    Thumbnail
    View/Open
    ners_009_01_012004.pdf (2.191Mb)
    Date
    2022
    Author
    Ghimire, Lekhnath;Waller, Edward
    Metadata
    Show full item record
    Abstract
    Ionizing radiation generates unpaired electrons or free radical centers in alanine. The electron paramagnetic resonance (EPR) detects, identifies, and quantifies these free radicals, proportional to the absorbed dose. The accurate measurements of low doses using EPR dosimetry with alanine are highly challenging due to (1) the weak EPR dosimetric signal from low dose alanine and measurement errors, (2) the sample anisotropy in crystalline alanine, and (3) the background signals from sample impurities. This study explores the feasibility of using the dose spiking EPR technique to overcome these challenges and decreases the detection limit up to 20 milligray (mGy) in a low dose measurement using EPR. The measurement errors from the sample anisotropy were reduced by rotating the samples relative to the constant magnetic field direction using a goniometer and averaging the resulting EPR spectra. This technique decreased the measurement errors at high doses; however, it was insufficient to decrease the detection limit and increase the measurement accuracy at low doses (<0.5 Gy). As a result, the high measurement accuracy at the high doses (>4 Gy) was exploited to increase the accuracy at the low doses using the dose spiking EPR technique. To this end, the low-dose alanine sample, undetectable and not reliably measurable in the X-band continuous wave (CW) EPR spectrometer, spikes with a high dose (4 Gy). Then, the total dose was measured and subtracted from a spike dose to get the initial low dose. This technique detected and measured the low doses with reliable accuracy (±10%). As a result, we concluded that this method has great potential to solve the low dose measurement problems in alanine dosimetry.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4288372
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV