    Accuracy of an Apparatus for Measuring Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty

    Thumbnail
    View/Open
    med_016_04_041008.pdf (1.095Mb)
    Date
    2022
    Author
    Torkan, Lawrence F.;Bryant, John T.;Bicknell, Ryan T.;Ploeg, Heidi-Lynn
    Metadata
    Show full item record
    Abstract
    Reverse shoulder arthroplasty (RSA) is used to treat patients with cuff tear arthropathy. Loosening remains to be one of the principal modes of implant failure and the main complication leading to revision. Excess micromotion contributes to glenoid loosening. This study sought to determine the predictive accuracy of an experimental system designed to assess factors contributing to RSA glenoid baseplate micromotion. A half-fractional factorial experiment was designed to assess 4 factors: central element type (screw versus peg), central element length (13.5 versus 23.5 mm), anterior-posterior peripheral screw type (locking versus nonlocking) and cancellous bone density (10 versus 25 pounds per cubic foot (pcf)). Four linear variable differential transducers (LVDTs) recorded micromotion from a stainless-steel disk surrounding a modified glenosphere. The displacements were used to interpolate micromotion at each peripheral screw position. The mean absolute percentage error (MAPE) was used to determine the predictive accuracy and error range of the system. The MAPE for each condition ranged from 6.8% to 12.9% for an overall MAPE of (9.5 ± 0.9)%. The system had an error range of 2.7 μm to 20.1 μm, which was lower than those reported by prior studies using optical systems. One of the eight conditions had micromotion that exceeded 150 μm. These findings support the use of displacement transducers, specifically LVDTs, as an accurate system for determining RSA baseplate micromotion in rigid polyurethane foam bone surrogates.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4288343
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV