• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Performance and Sensitivity Analysis of an Automated X-Ray Based Total Knee Replacement Mass-Customization Pipeline

    Thumbnail
    View/Open
    med_016_04_041007.pdf (2.527Mb)
    Date
    2022
    Author
    Burge, Thomas A.;Jeffers, Jonathan R. T.;Myant, Connor W.
    Metadata
    Show full item record
    Abstract
    The objective of this study was to outline a fully automated, X-ray-based, mass-customization pipeline for knee replacement surgery, thoroughly evaluate its robustness across a range of demographics, and quantify necessary input requirements. The pipeline developed uses various machine learning-based methods to enable the automated workflow. Convolutional neural networks initially extract information from inputted bi-planar X-rays, point depth and statistical shape models are used to reconstruct three-dimensional models of the subjects' anatomy, and finally computer-aided design scripts are employed to generate customized implant designs. The pipeline was tested on a range of subjects using three different fit metrics to evaluate performance. A digitally reconstructed radiograph method was adopted to enable a sensitivity analysis of input X-ray alignment and calibration. Subject sex, height, age, and knee side were concluded not to significantly impact performance. The pipeline was found to be sensitive to subject ethnicity, but this was likely due to limited diversity in the training data. Arthritis severity was also found to impact performance, suggesting further work is required to confirm suitability for use with more severe cases. X-ray alignment and dimensional calibration were highlighted as paramount to achieve accurate results. Consequentially, an alignment accuracy of ±5–10 deg and dimensional calibration accuracy of ±2–5%, are stipulated. In summary, the study demonstrated the pipeline's robustness and suitability for a broad range of subjects. The tool could afford substantial advantages over off-the-shelf and other customization solutions, but practical implications such as regulatory requirements need to be further considered.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4288342
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV