Show simple item record

dc.contributor.authorKeith Sharp, M.
dc.date.accessioned2022-12-27T23:14:37Z
dc.date.available2022-12-27T23:14:37Z
dc.date.copyright8/17/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn2642-6641
dc.identifier.otherjesbc_3_2_021003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4288197
dc.description.abstractAmbient House is a building that maintains indoor temperature within a comfortable range by controlling gains and losses from ambient sources and utilizing thermal mass to moderate temperature changes when the sources are unavailable. Previously, necessary building characteristics were determined for passive solar as the heating source and ventilation as the cooling source in 11 US climate zones. (Sharp, M.K., 2012, “Indoor Comfort Achieved Exclusively from Ambient Sources Across US Climates,” ASME J. Sol. Energy Eng. 143, (6), p. 061005.) It was noted that in hot climates, such as Phoenix, AZ, there are long periods during which outdoor temperature is too warm for cooling, necessitating large thermal mass to avoid indoor overheating. In this article, thermal mass requirements are compared between sky radiation and nighttime ventilation cooling in all 16 US climate zones, including marine subzones 3C and 4C and very cold and subarctic zones 7 and 8. It is shown that sky radiation provides shorter intervals of cooling unavailability and allows much smaller thermal mass to achieve year-round indoor comfort in the hot climates of Las Vegas, Miami, New Orleans, and Phoenix, while it provides no significant benefits in cool climates, where thermal mass is dictated more by the need to slow the decrease in indoor temperature during cloudy periods in the winter. In Fairbanks, AK (zone 8), in particular, the lack of significant solar gains for almost 3 months during the winter requires large thermal mass to maintain indoor comfort. Minimal thermal mass is needed to meet the small summer cooling demand, and both sky and ventilation cooling are sufficient.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleSky Radiation Decreases Thermal Mass Requirements to Achieve 100% Ambient Cooling in Hot US Climates
dc.typeJournal Paper
dc.journal.volume3
dc.journal.issue2
dc.journal.titleASME Journal of Engineering for Sustainable Buildings and Cities
dc.identifier.doi10.1115/1.4055110
dc.journal.fristpage21003
dc.journal.lastpage21003_10
dc.page10
dc.treeASME Journal of Engineering for Sustainable Buildings and Cities:;2022:;volume( 003 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record