Show simple item record

dc.contributor.authorMirza
dc.contributor.authorAsad;Ramaswamy
dc.contributor.authorSharan
dc.date.accessioned2022-08-18T12:54:47Z
dc.date.available2022-08-18T12:54:47Z
dc.date.copyright6/16/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_11_114501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4287086
dc.description.abstractThe Newtonian model has commonly been used to represent the viscosity of blood in the aorta, despite blood itself being a non-Newtonian fluid. This is justified where shear rates tend to be large. However, we hypothesized that using the Newtonian model to predict the hemodynamics on the aortic valve, particularly in those with severe calcifications, is inaccurate owing to valve leaflet geometry irregularities inducing multiple regions of low shear rates, <100 s−1, where a Newtonian model is invalid. We investigated the utility of three fluid viscosity models via quasi-static simulations: Newtonian, Carreau, and Quemada on a severely calcified aortic heart valve and compared their ability to capture important hemodynamic parameters of wall shear stress (WSS) and the oscillatory shear index (OSI). Our findings indicate that when the shear rates were large enough, >100 s−1, the use of a Newtonian model was justified. However, in spatial regions of relatively low shear rates, <100 s−1, specifically on the inner cusps of the fibrosa side of the valve, WSS calculations under a Newtonian model were found to be noticeably different when compared with their non-Newtonian, Carreau and Quemada counterparts. We hereby conclude that to facilitate more accurate computational flow simulations in severe aortic heart valve calcification, which is subjected to relatively large spatial regions of low shear (<100 s−1), a non-Newtonian model should be applied.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleImportance of Non-Newtonian Computational Fluid Modeling on Severely Calcified Aortic Valve Geometries—Insights From Quasi-Steady State Simulations
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue11
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4054630
dc.journal.fristpage114501-1
dc.journal.lastpage114501-6
dc.page6
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record