    Comparison of Balloon-Expandable Valve and Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A Patient-Specific Numerical Study

    Thumbnail
    View/Open
    bio_144_10_104501.pdf (1.791Mb)
    Date
    2022
    Author
    Li
    Jianming;Yan
    Wentao;Wang
    Wenshuo;Wang
    Shengzhang;Wei
    Lai
    Metadata
    Show full item record
    Abstract
    Transcatheter aortic valve replacement (TAVR) is a minimally invasive strategy for the treatment of aortic stenosis. The complex postoperative complications of TAVR were related to the type of implanted prosthetic valve, and the deep mechanism of this relationship may guide the clinical pre-operative planning. This technical brief developed a numerical method of TAVR to compare the outcome difference between balloon-expandable valve and self-expandable valve and predict the postoperative results. A complete patient-specific aortic model was reconstructed. Two prosthetic valves (balloon-expandable valve and self-expandable valve) were introduced to simulate the implantation procedure, and postprocedural function was studied with fluid–structure interaction method, respectively. Results showed similar stress distribution for two valves, but higher peak stress for balloon-expandable valve model. The balloon-expandable valve was associated with a better circular cross section and smaller paravalvular gaps area. Hemodynamic parameters like cardiac output, mean transvalvular pressure difference, and effective orifice area (EOA) of the balloon-expandable valve model were better than those of the self-expandable valve model. Significant outcome difference was found for two prosthetic valves. Balloon-expandable valve may effectively decrease the risk and degree of postoperative paravalvular leak, while self-expandable valve was conducive to lower stroke risk due to lower aortic stress. The numerical TAVR simulation process may become an assistant tool for prosthesis selection in pre-operative planning and postoperative prediction.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4287072
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV