• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Quantifying Joint Congruence With an Elastic Foundation

    Thumbnail
    View/Open
    bio_144_10_101003.pdf (1.240Mb)
    Date
    2022
    Author
    Burson-Thomas
    Charles B.;Dickinson
    Alexander S.;Browne
    Martin
    Metadata
    Show full item record
    Abstract
    The level of congruence between the articulating surfaces of a diarthrodial joint can vary substantially between individuals. Quantifying joint congruence using the most widespread metric, the “congruence index,” is not straightforward: the areas of the segmented bone that constitute the articular surfaces require accurate identification, their shape must be carefully described with appropriate functions, and the relative orientation of the surfaces measured precisely. In this work, we propose a new method of measuring joint congruence, which does not require these steps. First, a finite element (FE) simulation of an elastic layer compressed between each set of segmented bones is performed. These are then interpreted using the elastic foundation model, enabling an equivalent, but simpler, contact geometry to be identified. From this, the equivalent radius (quantification of joint congruence) is found. This defines the radius of a sphere contacting plane (or “ball on flat”) that produces an equivalent contact to that in each joint. The minimal joint space width (in this joint position) can also be estimated from the FE simulations. The new method has been applied to ten healthy instances of the thumb metacarpophalangeal (MCP) joint. The ten thumb MCPs had similar levels and variability of congruence as the other diarthrodial joints that have been characterized previously. This new methodology enables efficient quantification of joint congruence and minimal joint space width directly from CT- or MRI-derived bone geometry in any relative orientation. It lends itself to large data sets and coupling with kinematic models.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4287062
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV