Show simple item record

dc.contributor.authorLi
dc.contributor.authorJinhua;Zhang
dc.contributor.authorLan;Xing
dc.contributor.authorYuan;Liu
dc.contributor.authorRui
dc.date.accessioned2022-08-18T12:51:13Z
dc.date.available2022-08-18T12:51:13Z
dc.date.copyright5/10/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn1932-6181
dc.identifier.othermed_016_03_031007.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286974
dc.description.abstractThe continuum over tube applied to natural orifice transluminal endoscopic surgery (NOTES) should be flexible during insertion and provide sufficient stiffness upon arrival at the lesion. In order to satisfy these two properties, a variable stiffness continuum over tube was proposed. The over tube realizes stiffness variation through the heating and cooling of filling materials. Polyethylene glycol, cocoa butter, and gallium metal are selected as filling materials. Several experiments were designed to test its rigid and response characteristic, and suitable material was selected. The risk management test was carried out, and the frequency and risk level of the risk point were recorded. According to experimental data, the polyethylene glycol and gallium show better variable stiffness performance, with the 20 times stiffness variation range, and polyethylene glycol was selected as suitable materials for its low cost and nontoxic characteristic. The average heating time and cooling time of polyethylene glycol-filled over tube are 52.3 s and 36 s, respectively. Moreover, three kinds of high-frequency risk points including smoke, thread ejection, and uneven distribution of the material were found, and corresponding design improvement and use principle are proposed. The proposed continuum over tube can satisfy the requirement of colorectal NOTES for flexibility and stiffness of instruments, and the safety of the instrument can be improved by controlling high-frequency risk points with relevant methods.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Continuum Over Tube With Variable Stiffness for Transrectal NOTES
dc.typeJournal Paper
dc.journal.volume16
dc.journal.issue3
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4054343
dc.journal.fristpage31007-1
dc.journal.lastpage31007-8
dc.page8
dc.treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record