Show simple item record

dc.contributor.authorLittle
dc.contributor.authorJ. Paige;Green
dc.contributor.authorDaniel;Izatt
dc.contributor.authorMaree T.;Moloney
dc.contributor.authorGregory E.;Askin
dc.contributor.authorGeoffrey N.
dc.date.accessioned2022-08-18T12:51:01Z
dc.date.available2022-08-18T12:51:01Z
dc.date.copyright3/2/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn1932-6181
dc.identifier.othermed_016_02_025001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286971
dc.description.abstractOptimal patient positioning for spine surgery is vital for surgical success and the minimization of complications intra-/postoperatively. In patients with complex comorbidities, commercially available surgical positioning equipment is inadequate. To overcome this, a novel method was developed to create custom-fit patient-specific theater mattresses for patients undergoing spine surgery. An innovative digital workflow involving three-dimensional (3D) surface scanning, 3D simulation, and computer-aided design was developed to manufacture customized theater supports with patient-specific requirements. These supports offered the surgeon an enhanced ability to relieve load bearing on prominent anatomical features or where desired, to tailor the support surface to the patient's anatomy for lengthy surgery. The bespoke theater mattress was evaluated by whether the support resulted in a complication-free surgery. Using this new workflow, case examples for two patients with complex comorbidities were described. The spine surgeon and anesthetist reported the patient-specific custom mattresses were fit as per the required design, provided sufficient clearance around anatomical prominences and areas that required to be unloaded, had sufficient clearance for the anesthetic method and cannulation, provided excellent surgical access and stability during surgery, and postoperatively no soft tissue overload over bony prominence and implanted devices. Positive patient outcomes after successful lengthy surgical interventions were associated with these patient-specific, contoured mattress supports. Future projects will seek to utilize this technology for other types of surgeries and intra-operative positioning requirements, and for a broader demographic of patients in both the pediatric and adult setting.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePatient-Customized Theatre Mattress Supports for Spinal Surgery: A Pilot Study Presenting a Novel Engineering Virtual Design and Manufacturing Technique
dc.typeJournal Paper
dc.journal.volume16
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4053604
dc.journal.fristpage25001-1
dc.journal.lastpage25001-8
dc.page8
dc.treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record