    Development and Validation of a Physiological Testing Method for Sternal Closure Systems

    Thumbnail
    View/Open
    med_016_02_021011.pdf (1.199Mb)
    Date
    2022
    Author
    Kienle
    Annette;Renner
    Nadine;Bischoff
    Constanze
    Metadata
    Show full item record
    Abstract
    After a median sternotomy, the sternum has to be refixated using implants such as wires, plates, or clamps. However, there is still a lack of specifically applicable test methods to investigate the mechanical safety and effectiveness of such implant systems. The aim of this study was to develop a new test method that replicates the in vivo loads acting on the sternum and that is applicable to all types of sternal closure systems. Based on the scientific literature, a setup was developed that incorporates the physiological loads acting on the sternum during breathing (91 N) and coughing (328 N). These loads are applied to a sternum replicate at 5 Hz for approximately 1.8 × 106 cycles. This cycle number is assumed to represent the healing period. For validation, the new method was applied to two different sternal closure systems: a PEEK clamp system and wires. The new test method proved to be easily applicable. The validation tests with the two sternal closure systems showed reasonable and reproducible results regarding all outcome parameters. The pretension exerted by the implants significantly differed between the two implant groups and decreased after the first coughing cycles. The fracture gap separation during breathing also significantly different between the two test groups, but it was similar during coughing. No implant failed. Using this new test method, it is possible to compare sternal closure systems under reproducible, in vivo-based conditions and interpret their mechanical characteristics regarding their clinical safety and effectiveness.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4286964
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV