Show simple item record

dc.contributor.authorLuis Alberto Bedriñana
dc.contributor.authorMasanori Tani
dc.contributor.authorSusumu Kono
dc.contributor.authorMinehiro Nishiyama
dc.date.accessioned2022-08-18T12:29:24Z
dc.date.available2022-08-18T12:29:24Z
dc.date.issued2022/06/08
dc.identifier.other%28ASCE%29ST.1943-541X.0003395.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286699
dc.description.abstractThis paper presents an analytical procedure to assess the monotonic (envelope) force-deformation response (capacity curve) of unbonded post-tensioning precast concrete (UPT) walls with internal and external replaceable dampers. This procedure, which can also be used to design UPT walls, was compared and validated against experimental evidence. A close agreement (strength discrepancies of 2% on average) was found between the response predictions and experimental results. This agreement was maintained until peak strength was achieved. Moreover, fiber-based models were implemented to further study the cyclic behavior of UPT walls designed according to the proposed analytical procedure. The numerical models were accurate in representing the global cyclic behavior of UPT walls in terms of strength, displacement capacity, and energy dissipation; nonetheless, these models showed some discrepancies in capturing the residual drifts of some UPT walls with internal dampers. A parametric analysis was also conducted to explore the influence of some design parameters on the deformation capacity and energy dissipation of UPT walls. It was found that the ratio of damper reinforcement is critical for the energy dissipation and self-centering capacity of UPT walls, so ratios of 0.10 to 0.25 should be provided to follow the limit states indicated in this paper. Based on the results, the analytical procedure and limit states presented in this paper are considered suitable for UPT walls with external replaceable dampers under total axial load ratios equal or lower than 0.125.
dc.publisherASCE
dc.titleEvaluation of the Seismic Performance of Unbonded Post-Tensioned Precast Concrete Walls with Internal and External Dampers. II: Design Criteria and Numerical Research
dc.typeJournal Article
dc.journal.volume148
dc.journal.issue8
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0003395
dc.journal.fristpage04022106
dc.journal.lastpage04022106-21
dc.page21
dc.treeJournal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record