dc.description.abstractAs power systems include more intermittent renewable energy sources, energy storage solutions are needed to support them. Pumped hydro is a reliable alternative for long-term energy storage. A solution for bringing more pumped hydro into the power system is to upgrade existing hydropower plants into pumped hydro. To investigate this possibility, a case study with a complex tunnel system and multiple surge tanks along both the headrace and the tailrace tunnels is selected. A hydraulic scale model and validation methods were developed. The challenges in developing and validating complex models involving multiple surge tanks, throttles, head loss, and limited prototype information are detailed.
dc.publisherASCE
dc.titleHydraulic Scale Modeling of Mass Oscillations in a Pumped Storage Plant with Multiple Surge Tanks
dc.typeJournal Article
dc.journal.volume148
dc.journal.issue9
dc.journal.titleJournal of Hydraulic Engineering
dc.identifier.doi10.1061/(ASCE)HY.1943-7900.0001990
dc.journal.fristpage05022002
dc.journal.lastpage05022002-9