Show simple item record

dc.contributor.authorWilmanns, Nadja
dc.contributor.authorBeckmann, Agnes
dc.contributor.authorNicolini, Luis Fernando
dc.contributor.authorHerren, Christian
dc.contributor.authorSobottke, Rolf
dc.contributor.authorHildebrand, Frank
dc.contributor.authorSiewe, Jan
dc.contributor.authorKobbe, Philipp
dc.contributor.authorMarkert, Bernd
dc.contributor.authorStoffel, Marcus
dc.date.accessioned2022-05-08T09:42:07Z
dc.date.available2022-05-08T09:42:07Z
dc.date.copyright2/15/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_07_071001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285474
dc.description.abstractLumbar lordotic correction (LLC), the gold standard treatment for sagittal spinal malalignment (SMA), and its effect on sagittal balance have been critically discussed in recent studies. This paper assesses the biomechanical response of the spinal components to LLC as an additional factor for the evaluation of LLC. Human lumbar spines (L2L5) were loaded with combined bending moments in flexion (Flex)/extension (Ex) or lateral bending (LatBend) and axial rotation (AxRot) in a physiological environment. We examined the dependency of AxRot range of motion (RoM) on the applied bending moment. The results were used to validate a finite element (FE) model of the lumbar spine. With this model, the biomechanical response of the intervertebral discs (IVD) and facet joints under daily motion was studied for different sagittal alignment postures, simulated by a motion in Flex/Ex direction. Applied bending moments decreased AxRot RoM significantly (all P &lt
dc.description.abstract 0.001). A stronger decline of AxRot RoM for Ex than for Flex direction was observed (all P &lt
dc.description.abstract 0.0001). Our simulated results largely agreed with the experimental data (all R2 &gt
dc.description.abstract 0.79). During the daily motion, the IVD was loaded higher with increasing lumbar lordosis (LL) for all evaluated values at L2L3 and L3L4 and posterior annulus stress (AS) at L4L5 (all P &lt
dc.description.abstract 0.0476). The results of this study indicate that LLC with large extensions of LL may not always be advantageous regarding the biomechanical loading of the IVD. This finding may be used to improve the planning process of LLC treatments.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleBiomechanical In Vitro and Finite Element Study on Different Sagittal Alignment Postures of the Lumbar Spine During Multiaxial Daily Motion
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue7
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4053083
dc.journal.fristpage71001-1
dc.journal.lastpage71001-9
dc.page9
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 007
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record