• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Novel QT-Interval Analysis Method Based on Continuous Wavelet Transform and Philips Algorithm

    Thumbnail
    View/Open
    jesmdt_005_01_011007.pdf (889.2Kb)
    Date
    2022
    Author
    İşcan, Mehmet
    Yilmaz, Abdurrahman
    Vural, Berkem
    Yilmaz, Cüneyt
    Tuzcu, Volkan
    Metadata
    Show full item record
    Abstract
    QT surveillance is the most vital appliance to detect the possibility of sudden death sourced by using pro-arrhythmic drugs treating abnormal conditions in the heart. The repolarization of ventricles makes QT interval surveillance difficult since noisy conditions and individual cardiac situations. Besides, an automated QT algorithm is crucial due to a manual QT measurement with some disadvantages such as fatigue condition in reading long records. In this study, a fully novel automated method combining Continuous Wavelet Transform and Philips method was established to perform QT interval analysis. Electrocardiogram recordings were obtained from PhyisoNet database marked by manual and standard automated methods. The proposed algorithm had scores of 15.46 and 11.87 millisecond mean error with 11.85 and 9.91 millisecond standard deviation in terms of gold and silver standards, respectively. Also, the entire QT database was utilized in order to test the algorithm performance with the score of 12.89 and 9.76 millisecond mean and standard deviation errors, respectively. The present algorithm performance had scores of −0.21 ± 7.81 at golden standard, and −4.10 ± 18.21 millisecond error for the whole QT database tests, respectively. The proposed algorithm is attained to more stable and robust results with a higher performance than the previous comparable studies.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4285467
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV