• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Energy Resources Technology
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Energy Resources Technology
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Performance Analysis of a Novel Cascade Vapor Compression System for Small-Scale Desalination and Cooling

    Thumbnail
    View/Open
    jert_144_9_092102.pdf (1.823Mb)
    Date
    2022
    Author
    Alkhulaifi, Yousif M.
    Alsadah, Jihad H.
    Mokheimer, Esmail M. A.
    Metadata
    Show full item record
    Abstract
    The demand for improving living standards has led to increasing freshwater consumption and comfort cooling, requiring significant performance improvements. In this regard, a novel and efficient cascade refrigeration system (CRS) for simultaneous generation of considerable freshwater and cooling effect is proposed. The system does not require dedicated components for desalinating seawater because it is a by-product of the proposed CRS. Utilizing the cascade configuration enhances energy efficiency by lowering the compression work while improving energy recovery by utilizing the heat rejected from the condenser of low-temperature cycle to vaporize seawater for desalination in the evaporator of the high-temperature cycle of the proposed cascade system. A mathematical model of the innovative system based on thermodynamic and economic principles has been developed and utilized to predict the proposed system's thermal performance and cost-savings. A comprehensive analysis has been conducted to study the effect of multiple parameters such as the evaporator, condenser, and brine boiling temperatures. The main studied parameters were coefficient of performance (COP), gain output ratio (GOR), freshwater production, and total cost-savings. For a 10 tons of refrigeration (TR) unit, the freshwater production was between 56.11 and 73.36 kg/h, with cost-savings reaching 2226 US$/year. It was found that the freshwater production increased with condenser and brine boiling temperature but decreased with evaporator temperature. The COP improvement can be as much as 26% over the reference cooling system without desalination.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4285442
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV