Show simple item record

dc.contributor.authorTeles, Mavd P. R.
dc.contributor.authorIsmail, Kamal A. R.
dc.date.accessioned2022-05-08T09:40:27Z
dc.date.available2022-05-08T09:40:27Z
dc.date.copyright2/4/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0195-0738
dc.identifier.otherjert_144_9_091301.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285439
dc.description.abstractLow concentration collectors are usually recommended for water heating and refrigeration systems. The literature reveals lack of information on numerical modeling, experimental data, and thermal performance of eccentric evacuated double tube solar collectors. This study is focused on eccentric solar collectors since this arrangement allows adequate concentration for achieving relatively high temperatures while having small size and occupying less space. The effects of the vacuum in the annular space and reflective film on the enhancement of working fluid heating and overall thermal performance were also assessed. An in-house numerical code using the finite volume method was used to discretize the conservation equations and the predictions were validated by experimental results obtained from an experimental rig that was constructed and instrumented for outdoor tests. The experiments were performed in the city of Campinas-Brazil during the autumn season. The investigated versions of the eccentric double tube solar collector include a version with a reflective film and vacuum, a second version with a reflective film but without vacuum, a third arrangement without a reflective film but with vacuum, and finally a version without both a reflective film and vacuum. The results showed that the version with reflective film and vacuum demonstrated high efficiency achieving 89%. The lowest efficiency of 42% was achieved by the version without both reflective film and vacuum. The comparative analysis of the four versions shows that the incorporation of reflective film increases the collector efficiency by 28%, while the vacuum increases the efficiency by about 1.3%.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental and Numerical Assessments of the Effects of Vacuum and Solar Film on the Performance of a Low Concentration Eccentric Solar Collector
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue9
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4052982
dc.journal.fristpage91301-1
dc.journal.lastpage91301-14
dc.page14
dc.treeJournal of Energy Resources Technology:;2022:;volume( 144 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record