Show simple item record

dc.contributor.authorAycock, Kenneth N.
dc.contributor.authorVadlamani, Ram Anand
dc.contributor.authorJacobs, Edward J., IV
dc.contributor.authorImran, Khan Mohammad
dc.contributor.authorVerbridge, Scott S.
dc.contributor.authorAllen, Irving C.
dc.contributor.authorManuchehrabadi, Navid
dc.contributor.authorDavalos, Rafael V.
dc.date.accessioned2022-05-08T09:38:11Z
dc.date.available2022-05-08T09:38:11Z
dc.date.copyright2/15/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_06_061003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285385
dc.description.abstractWhile the primary goal of focal therapy for prostate cancer (PCa) is conserving patient quality of life by reducing oncological burden, available modalities use thermal energy or whole-gland radiation which can damage critical neurovascular structures within the prostate and increase risk of genitourinary dysfunction. High-frequency irreversible electroporation (H-FIRE) is a promising alternative ablation modality that utilizes bursts of pulsed electric fields (PEFs) to destroy aberrant cells via targeted membrane damage. Due to its nonthermal mechanism, H-FIRE offers several advantages over state-of-the-art treatments, but waveforms have not been optimized for treatment of PCa. In this study, we characterize lethal electric field thresholds (EFTs) for H-FIRE waveforms with three different pulse widths as well as three interpulse delays in vitro and compare them to conventional irreversible electroporation (IRE). Experiments were performed in non-neoplastic and malignant prostate cells to determine the effect of waveforms on both targeted (malignant) and adjacent (non-neoplastic) tissue. A numerical modeling approach was developed to estimate the clinical effects of each waveform including extent of nonthermal ablation, undesired thermal damage, and nerve excitation. Our findings indicate that H-FIRE waveforms with pulse durations of 5 and 10 μs provide large ablations comparable to IRE with tolerable levels of thermal damage and minimized muscle contractions. Lower duration (2 μs) H-FIRE waveforms exhibit the least amount of muscle contractions but require increased voltages which may be accompanied by unwanted thermal damage.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental and Numerical Investigation of Parameters Affecting High-Frequency Irreversible Electroporation for Prostate Cancer Ablation
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue6
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4053595
dc.journal.fristpage61003-1
dc.journal.lastpage61003-11
dc.page11
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail
This item appears in the following Collection(s)

Show simple item record