Show simple item record

dc.contributor.authorFewster, Kayla M.
dc.contributor.authorGuo, Joyce R.
dc.contributor.authorZehr, Jackie D.
dc.contributor.authorBarrett, Jeff M.
dc.contributor.authorLaing, Andrew C.
dc.contributor.authorCallaghan, Jack P.
dc.date.accessioned2022-05-08T09:32:39Z
dc.date.available2022-05-08T09:32:39Z
dc.date.copyright1/21/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_05_051010.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285263
dc.description.abstractLow back pain (LBP) is frequently reported following rear impact collisions. Knowledge of how the facet joint capsule (FJC) mechanically behaves before and after rear impact collisions may help explain LBP development despite negative radiographic evidence of gross tissue failure. This study quantified the Green strain tensor in the facet joint capsule during rotation and translation range-of-motion tests completed before and following an in vitro simulation of a rear impact collision. Eight FSUs (4 C3-C4, 4 C5-C6) were tested. Following a preload test, FSUs were flexed and extended at 0.5 deg/s until an ±8 N·m moment was achieved. Anterior and posterior joint translation was then applied at 0.2 mm/s until a target ±400 N shear load was imposed. Markers were drawn on the facet capsule surface and their coordinates were tracked during pre- and postimpact range-of-motion tests. Strain was defined as the change in point configuration relative to the determined neutral joint posture. There were no significant differences (p &gt
dc.description.abstract0.05) observed in all calculated FJC strain components in rotation and translation before and after the simulated impact. Our results suggest that LBP development resulting from the initiation of strain-induced mechanoreceptors and nociceptors with the facet joint capsule is unlikely following a severe rear impact collision within the boundaries of physiological joint motion.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleStrain Response in the Facet Joint Capsule During Physiological Joint Rotation and Translation Following a Simulated Impact Exposure: An In Vitro Porcine Model
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue5
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4053207
dc.journal.fristpage51010-1
dc.journal.lastpage51010-6
dc.page6
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record