• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of the Load Reduction Performance Via a Suspended Backpack With Adjustable Stiffness

    Thumbnail
    View/Open
    bio_144_05_051001.pdf (2.419Mb)
    Date
    2021
    Author
    Yang, Zhenhua
    Huang, Ledeng
    Zeng, Ziniu
    Wang, Ruishi
    Hu, Ruizhe
    Xie, Longhan
    Metadata
    Show full item record
    Abstract
    Backpacks are essential for travel but carrying a load during a long journey can easily cause muscle fatigue and joint injuries. Previous studies have suggested that suspended backpacks can effectively reduce the energy cost while carrying loads. Researchers have found that adjusting the stiffness of a suspended backpack can optimize its performance. Therefore, this paper proposes a stiffness-adjustable suspended backpack
     
    the system stiffness can be adjusted to suitable values at different speeds. The stiffness of the suspended backpack with a 5-kg load was designed to be 690 N/m for a speed of 4.5 km/h, and it was adjusted to 870 and 1050 N/m at speeds of 5.5 and 6.5 km/h, respectively. The goal of this study was to determine how carrying a stiffness-adjustable suspended backpack affected performance while carrying a load. Six healthy participants participated in experiments where they wore two backpacks under three conditions: the adjustable-stiffness suspended backpack condition (S_A), the unadjustable-stiffness suspended backpack condition (S_UA), and the ordinary backpack condition (ORB). Our results showed that the peak accelerations, muscle activities, and peak ground reaction forces in the S_A condition were reduced effectively by adjusting the stiffness to adapt to different walking speeds
     
    this adjustment decreased the metabolic cost by 4.21 ± 1.21% and 2.68 ± 0.88% at 5.5 km/h and 4.27 ± 1.35% and 3.38 ± 1.31% at 6.5 km/h compared to the ORB and S_UA, respectively.
     
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4285163
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV