• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Scale-Resolving Simulations of Steady and Pulsatile Flow Through Healthy and Stenotic Heart Valves

    Thumbnail
    View/Open
    bio_144_03_031010.pdf (4.449Mb)
    Date
    2021
    Author
    Hoeijmakers, M. J. M. M.
    Morgenthaler, V.
    Rutten, M. C. M.
    van de Vosse, F. N.
    Metadata
    Show full item record
    Abstract
    Blood-flow downstream of stenotic and healthy aortic valves exhibits intermittent random fluctuations in the velocity field which are associated with turbulence. Such flows warrant the use of computationally demanding scale-resolving models. The aim of this work was to compute and quantify this turbulent flow in healthy and stenotic heart valves for steady and pulsatile flow conditions. Large eddy simulations (LESs) and Reynolds-averaged Navier–Stokes (RANS) simulations were used to compute the flow field at inlet Reynolds numbers of 2700 and 5400 for valves with an opening area of 70 mm2 and 175 mm2 and their projected orifice-plate type counterparts. Power spectra and turbulent kinetic energy were quantified on the centerline. Projected geometries exhibited an increased pressure-drop (&gt
     
    90%) and elevated turbulent kinetic energy levels (&gt
     
    147%). Turbulence production was an order of magnitude higher in stenotic heart valves compared to healthy valves. Pulsatile flow stabilizes flow in the acceleration phase, whereas onset of deceleration triggered (healthy valve) or amplified (stenotic valve) turbulence. Simplification of the aortic valve by projecting the orifice area should be avoided in computational fluid dynamics (CFD). RANS simulations may be used to predict the transvalvular pressure-drop, but scale-resolving models are recommended when detailed information of the flow field is required.
     
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4284908
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse
    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects
    My Account
    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV